CONNECTION STRING FOR IBM INFORMIX ODBC DRIVER DOWNLOAD

  • March 27, 2019

If your application is single threaded, you might have better performance with this property. CP Windows Connection Lifetime When a connection is returned to the pool, the creation time of the connection is compared with the current time, and the connection is destroyed if that time span in seconds exceeds the value specified by connection lifetime. The connection string is parsed immediately after being set. Resetting the ConnectionString on a closed connection resets all connection string values and related properties, including the password. Other errors can be found only when an attempt is made to open the connection. If another user has already opened the database, exclusive access is denied, an error is returned, and the database is not opened. Using these statements without proper management can lead to unexpected results.

Uploader: Nikosho
Date Added: 10 July 2014
File Size: 41.82 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 58298
Price: Free* [*Free Regsitration Required]

The name or alias of the instance of the Informix server to which to connect. The communication protocol used between dobc CreateConnection and the database server.

Informix Connection String Samples –

The minimum number of connections allowed in the pool. Resetting the connection string resets all connection string values, including the password. Reduces the number of round trips to the server for result-set queries. Send feedback Examples exchange Troubleshooting.

The connection string is parsed immediately after being set. If any of those are missing, the server ignores the remaining attributes and next checks the environmental infomix, followed by the values in specified in setnet If another user has already opened the database, exclusive access is denied, an error is returned, and the database is not opened.

  AN983B NIC DRIVER DOWNLOAD

ConnectionString property

When set to true or y for yes, any string within double quotes ” is treated as an identifier, and any string within single quotes ‘ is treated as a string literal. The name or IP address iibm the machine on which the Informix server is running.

Required if the client machine or user account is not trusted by the host. Recommended only for forward-only retrieval of data. When a connection is returned to the pool, the creation time of the connection is compared with the current time, and the connection is destroyed if that time span in seconds exceeds the value specified by connection lifetime. You can switch a server-only connection to a database connection by using the ChangeDatabase method.

Resetting the ConnectionString on a closed connection resets all connection string values and related properties, including the password. If errors in syntax are found when parsing, a runtime exception, ArgumentException, is returned. The size in bytes of the buffers used to send data to or from the vonnection. Some of the connection string values have corresponding read-only properties.

ConnectionString property

If you set the Persist Security Info attribute to false the defaultif the connection has ever been opened, the returned connection string will not contain any security information. The maximum number of connections allowed in the pool. When the connection string is set, all of these properties are updated, except when an error is detected.

  FOCUSRITE SAFFIRE LINUX DRIVER DOWNLOAD

If you set the Persist Security Info attribute to true, the returned connection string contains security information. If the connection has not been opened, the returned connection string does contain security information, regardless of the setting of Persist Security Info.

The Server attribute is mandatory in all situations. NET Provider does not automatically recognize when these commands are issued.

IfxConnection properties return those settings contained in the ConnectionString as well as default values or values gathered elsewhere.

If no database is specified, a server-only connection is created. Valid values are No, 0, Yes, or 1.

Maximum value is 2GB. The default value of the ConnectionString property is an intormix string. If your application is single threaded, you might have better performance with this property.

The password associated with the User ID. Other errors can be found only when an attempt is made to open the connection. However, you must be certain that your queries are correct, otherwise an error will result.